Delfield 2194202 Thermostat functions as a vital temperature management device which specifically regulates food warmer heating performance in commercial kitchens. The thermostat incorporates a 3/8" x 5" copper bulb with a 60" capillary to provide temperature control for food applications reaching up to 220°F. Vertical mounting capability stands out as a distinctive feature of this model because it enables different installation positions. The thermostat provides secure screw terminal connections to operate with the Delfield Foodwarmer KH2-NU. Your establishment's service quality will improve through the use of the 2194202 which maintains dishes at their ideal temperature in your food warming equipment.

Dimensions

  • Length: 5.3 In
  • Width: 1.7 In
  • Height: 3 In
  • Weight: 0.5 lbs
https://partsfe.com/media/catalog/product/d/e/delfield-2194202-thermostat-3-8-x-5-60-cap-66394-2.jpg

Product Notes

  • T'Stat- S, Temp Off-220 F,
  • 3/8" X 5" Copper Bulb, 60" Cap, 2 Screw Terminals,
  • No Screws
  • Mount 1 Vert, .187" D-Stem Flat Left
  • For Knob Use # 221415 Off-10-1
  • Delfield Foodwarmer Kh2-Nu
DELFIELD:
Write Your Own Review
You're reviewing:Delfield 2194202 Thermostat 3/8" X 5" 60" Cap
Your Rating
Customer Questions
What maintenance is required for the Delfield 2194202 Thermostat?

Regularly inspect the thermostat for proper calibration and ensure the sensing bulb is clean and correctly positioned. Check the capillary tube for kinks or damage and verify tight electrical connections. Remove grease buildup that may affect performance. Always disconnect power before servicing to ensure better maintenance.

What are common issues with the Delfield 2194202 Thermostat?

  • Inaccurate or inconsistent temperature control.
  • Unit not reaching or maintaining set temperature.
  • Damaged or kinked capillary tube.
  • Loose or faulty electrical terminals.
  • Delayed response to temperature changes.
  • Thermostat failing to cycle heating elements properly.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power and let the unit cool completely before starting work.

Step2: Remove control panel and detach old thermostat, noting wiring and capillary routing path.

Step3: Install new thermostat, securing the control body and routing the capillary tube without kinks.

Step4: Position sensing bulb properly in the temperature zone and reconnect wiring to correct terminals.

Step5: Restore power, test temperature control response, and ensure better , stable operation.