Product Notes

  • Steamer Timer, (Atmospheric), Round With D-Stem,
  • 2 Switches, 60 Min , 24V, 1-1/16" Long Stem
  • (Comes With Shaft Seal 101145, # 32-1324 )
  • Groen Steamer Hy-3E, Hy-6G
Write Your Own Review
You're reviewing:Groen Z096826S Timer
Your Rating
Customer Questions
What maintenance is required for the Groen Z096826S Electric Timer?

Clean the timer exterior and ensure electrical connections remain tight and corrosion-free. Periodically test timing accuracy and switch response. Avoid moisture exposure and verify correct supply to prevent irregular operation or premature electrical component damage.

What are common issues with the Groen Z096826S Electric Timer?

  • Inaccurate or inconsistent timing cycles.
  • Switch failure or delayed response.
  • Electrical contact wear causing intermittent operation.
  • Power supply issues leading to complete timer shutdown.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off main power supply and confirm isolation using a tester.

Step2: Remove old timer carefully and document wiring positions for reference.

Step3: Connect line, load, and control wires according to the wiring diagram.

Step4: Mount the timer securely inside the control panel using screws.

Step5: Restore power and test the 60-minute timing cycle for accuracy.

Step6: Ensure proper grounding, avoid live-wire contact, and follow electrical safety precautions.