Step1: Disconnect power to the oven and allow it to cool completely before servicing.
Step2: Locate the temperature probe inside the oven cavity and remove the mounting screws.
Step3: Carefully pull the probe forward and disconnect the wire connector from the harness.
Step4: Connect the new temperature probe to the wiring harness and position it through the mounting opening.
Step5: Secure the probe with the original mounting screws, ensuring proper placement inside the oven.
Step6: Restore power and test oven operation to verify accurate temperature sensing and control.