What maintenance is required for the APW 1473400 Thermopile?

Regularly inspect the thermopile for dirt, corrosion, or loose connections that may affect performance. Clean the sensor tip gently to ensure proper heat detection. Check wiring for damage. Always turn off gas supply before servicing to ensure safety.

What are common issues with the APW 1473400 Thermopile?

  • Weak or no millivolt output causing pilot failure.
  • Inconsistent voltage leading to burner not staying lit.
  • Damaged or frayed leads affecting signal transmission.
  • Poor flame contact reducing thermopile efficiency.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas and power to appliance and allow it to cool completely before servicing for safety.

Step2: Remove old thermopile from burner assembly and note original positioning for correct replacement.

Step3: Install new thermopile in proper flame path and secure mounting firmly.

Step4: Reconnect leads, restore power and gas, test ignition and flame stability, check for leaks.

Step5: Ensure no gas leaks and verify proper operation before leaving unit unattended.