Garland GL2200602 Thermocouple 24"

Special Price $39.59 Regular Price $70.69
In stock
SKU
GL2200602
The Garland GL2200602 Thermocouple 24" is a temperature sensor for commercial cooking appliances. It measures the presence of the flame and the temperature, which is then sent to the control system to control the flow of gas. This thermocouple is a vital safety and working component of the appliance in that it ensures that the system does not switch on when there is no flame present, nor does it switch off when it becomes ignited. It is often fitted in restaurants, helping to ensure the correct monitoring of temperature and adding to the stable work of commercial cooking appliances.

Dimensions

  • Length: 6 In
  • Width: 3 In
  • Height: 0.7 In
  • Weight: 0.1 lbs
https://partsfe.com/media/catalog/product/g/a/garland-gl2200602-sit-type-24-metric-thermocouple-20-30-mv-9mm-thread-for-oven-36475-2.jpg

Product Notes

  • 24" Metric Thermocouple, Sit Type, 20-30 Mv
  • 9Mm Thread (M9-1.0)
  • Garland
  • Oven Gd24Gff,
  • G24-15Hfsd, Gd-152Hff, Gd-303Hff, Gd-304-Hff, Ms54R, Ms54Rc,
  • Ms54Rce, Ms54Re, Ms54S, Ms54Se, Ms54T, Ms54Te, Mst43R,
  • Mst43Rc, Mst43Rce, Mst43Re, Mst43S, Mst43Se, Mst43T,
  • Mst43Te, Mst44R, Mst44Rc, Mst44Rce, Mst44Re, Mst44S,
  • Mst44Se, Mst44T, Mst44Te, Mst4S, Mst4Se, Mst4T, Mst4Te,
  • Mst54R, Mst54Rc, Mst54Rce, Mst54Re, Mst54S, Mst54Se, Mst54T,
  • Mst54Te
Write Your Own Review
You're reviewing:Garland GL2200602 Thermocouple 24"
Your Rating
Customer Questions
What maintenance is required for the Garland GL2200602 Thermocouple?

Regularly inspect the thermocouple for signs of wear, corrosion, or loose connections. Keep the probe clean and properly positioned in the flame for accurate readings. Ensure secure threading and avoid overtightening. Always turn off gas supply before servicing to prevent accidents.

What are common issues with the Garland GL2200602 Thermocouple?

  • Weak or inconsistent voltage output causing pilot failure.
  • Loose or damaged thread connections.
  • Improper flame contact leading to shutdown.
  • Corrosion or wear affecting signal transmission.
  • Intermittent oven ignition problems.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas supply and electrical power; allow oven to cool completely for safety.

Step2: Remove oven panel and disconnect old thermocouple from gas valve and burner assembly.

Step3: Install new thermocouple into burner bracket and secure 9mm threaded connection to valve.

Step4: Ensure proper alignment near pilot flame; tighten fittings without over-torquing.

Step5: Restore gas, test ignition, and check for stable millivolt signal and flame safety cutoff.