The Keating P16170L Flame Switch is a safety component for pilot light systems. It has mercury and a 26" cap with a bulb 1/8" x 2-3/16". It is a normally open pilot safety switch operating to provide system safety by sensing the presence or absence of a flame. It is mounted using a metal plate with two mounting holes, 1/4" tab terminals, N.O. & COM connections, and two sheet metal screws. Older Keating systems are ideal, newer models require a conversion kit. The reliability and safety in industrial systems is improved by this device.

Dimensions

  • Length: 3.5 In
  • Width: 3.5 In
  • Height: 1.5 In
  • Weight: 0.2 lbs
https://partsfe.com/media/catalog/product/p/1/p16170l-flame-switch-91501.jpg

Product Notes

  • Flame Switch, Contains Mercury, Harper Wyman,
  • 26" Cap, Bulb 1/8" X 2-3/16", Normally Open Pilot Safety,
  • Metal Mounting Plate W/ 2 Ea Mt Holes Ctrs 1-5/8".
  • 2Ea 1/4" Tab Terminals, N.O.& Com,
  • 2 Sheet Metal Mt Screws,
  • Includes Instructions
  • This Is The Old Style Keating Flame Switch.
  • For New Style Keating Flame Switch, Keating Supplies A
  • Conversion Kit. Model And Serial #S Required. Special Order
More Information
Disable SaleableNo
Write Your Own Review
You're reviewing: P16170L Flame Switch
Your Rating
Customer Questions
What maintenance is required for the Keating P16170L Flame Switch?

Clean contacts and inspect wiring for corrosion or damage. Ensure proper alignment with the flame sensor. Proper maintenance supports accurate flame detection and secure appliance operation.

What are the common issues with the Keating P16170L Flame Switch?

  • Failure to detect flame.
  • Corroded or loose electrical connections.
  • Intermittent operation causing ignition issues.
  • Misalignment affecting sensor performance.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas and power before servicing the appliance.

Step2: Remove access panel to locate the existing flame switch.

Step3: Disconnect wiring from the old switch carefully.

Step4: Unscrew and remove the old flame switch.

Step5: Install the new flame switch in the same position.