The Keating P45246L Thermostat RX is a temperature controller that can be used in compatible cooking equipment. It detects the heat in the equipment and switches on the heating system to sustain the chosen temperature. It is mounted on the control panel and is linked to a sensing element placed within the cooking cavity, and it controls the operation of the burners or elements. This thermostat is a main control element in the commercial kitchen setting that assists in maintaining steady temperatures during the cooking process.

Dimensions

  • Length: 9 In
  • Width: 2 In
  • Height: 2.5 In
  • Weight: 0.7 lbs
https://partsfe.com/media/catalog/product/p/4/p45246l-thermostat-52206.jpg

Product Notes

  • Thermostat, [ Type - Rx ] [ Temp 245-406 ]
  • [ Bulb 5/16" X 10" ] [ Cap 30" ]
  • [ Ss Stuff Box 1/4" Mpt X 5/16" Cct ]
  • For Pointer Knob Use # 22-1189
  • For Dial Plate Use # 22-1190
  • Keating Fryer 10X11 14 Aa,10X11 14 Bb,10X11 14 Cmg,10X11 14
  • Ts,14Aa,18-20 Aa,18-24 Bb,18-24 Ts,18Aa,2009,20Aa,34X24
  • Bb,34X24 Ts,Aa,Aa2000,Bb,Cmg,Gasfryerpre2000,Ts
KEATING:
Write Your Own Review
You're reviewing:Keating P45246L Thermostat RX
Your Rating
Customer Questions
What maintenance is required for the Unknown P45246L Thermostat?

For optimal performance, clean the thermostat probe and housing regularly to prevent dust buildup affecting temperature sensing. Inspect wiring and connections for looseness or corrosion. Regular checks ensure accurate temperature control and safe operation in high-heat applications.

What are common issues with the Unknown P45246L Thermostat?

  • Inaccurate temperature regulation due to sensor drift.
  • Failure to activate heating/cooling system.
  • Wiring damage or loose connections.
  • Mechanical wear causing inconsistent switching.
  • Overheating leading to premature malfunction.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Disconnect power and ensure equipment is fully cooled.

Step2: Remove control panel to access existing thermostat assembly.

Step3: Label and disconnect all wiring from old unit.

Step4: Remove mounting hardware and carefully withdraw capillary bulb.

Step5: Install new thermostat, routing capillary without sharp bends.

Step6: Secure bulb in sensing area and reconnect wires to matching terminals.

Step7: Restore power and test temperature range for proper cycling and safety cutoff.