Step1: Shut off main gas supply and electrical power to fryer, ensure unit is cool and ventilated.
Step2: Remove existing safety bleed actuator and pilot burner assembly carefully, noting connection layout.
Step3: Position new actuator, align mounting points, and secure firmly without over-tightening fittings.
Step4: Connect 1/2" FPT gas line and pilot tubing; check tight seals.
Step5: Install pilot burner and ensure correct orientation and clearance.
Step6: Restore gas, test ignition, and perform leak check using soap solution before operation.