Southbend 1191727 Range RX Electric Thermostat Millivolt Max Temp 575°F 60" CAP
Dimensions
- Weight: 0.851 lbs
Electrical Control:
Regulates the heating system by controlling the electrical signal that coordinates burner operation within compatible commercial ranges. The thermostat responds to temperature conditions and manages the millivolt control circuit to maintain the selected heat level during operation. By linking temperature sensing with heating control, it supports consistent thermal regulation and allows the appliance to adjust heat output according to cooking requirements. The component provides a control point between the user-selected temperature setting and the range’s heating system.
Heating System Control:
Within the range's gas heating system, the thermostat works with the burner and gas control components to regulate heat output during cooking. By responding to temperature changes, it coordinates burner operation to maintain the selected cooking temperature throughout the operating cycle, supporting consistent heating conditions within the cooking equipment.
Replacement Guidelines:
Replace the Southbend 1191727 Range Thermostat 550°F Millivolt RX when wear, physical damage, deterioration, or functional failure affects its ability to regulate temperature according to the equipment's intended control requirements. Inspect the thermostat and related control connections for conditions that could affect temperature control operation. Replace the component when it can no longer maintain its intended function within the range of the temperature control system.
Common Failure Symptoms:
Equipment Compatibility:
The Southbend 1191727 Range Thermostat 550°F Millivolt RX is used with Southbend commercial gas ranges requiring this thermostat configuration. Verify the equipment model number, part number, thermostat type, and temperature rating before purchase to confirm the correct application.
Technical Specifications:
Brand: Southbend
Part Number: 1191727
Product Name: RX-Millivolt Thermostat
Equipment Type: Range
Maximum Temperature Rating: 550°F
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Step1: Disconnect power and shut off gas supply if applicable.
Step2: Remove control panel access screws.
Step3: Disconnect wiring leads and capillary sensing bulb from the existing thermostat.
Step4: Mount the new thermostat and route the 60" capillary tube properly.
Step5: Reconnect wiring, secure the panel, and verify temperature regulation.