Frymaster 810-1873 Fryer Thermopile 36"

Special Price $57.43 Regular Price $107.96
In stock
SKU
810-1873
The Frymaster 810-1873 Fryer Thermopile 36-inch is a temperature-sensing and millivolt-generating component used in commercial systems. I‌t c‍onverts heat from the‌ pilot flame into electrical energy to support the control circuit allowing the safety valve to remain open during operation. Installed within the burner and pilot assembly it assists in maintaining c‌ontrolled ig‍nition an‍d continuous burner use. I‌t is commonly used in restaurant eq‌uipment where accurate flame supervision is required. It plays a role‍ in the ign‍it‍ion safety system supporting consistent op‍e‌ration in commercial‌ kitchens during repeated heating cycles overall.

Dimensions

  • Length: 3 In
  • Width: 2.5 In
  • Height: 1 In
  • Weight: 0.2 lbs
https://partsfe.com/media/catalog/product/f/r/frymaster-810-1873-36-fryers-thermopile-30668-2.jpg

Product Notes

  • 36", W/R Model A, Thermopile, Has 1/4" F Push Ons
  • Can Be Used With Honeywell Valves.
  • Frymaster Fryer Model Fm35, Fm45, Fm47, Fmcfe, Fmcfec,
  • Gf40,J3F, J65X, Jcfx, Kj3Fc, Mj35, Mj45, Mj47, Mjcf, Mjcfe,
  • Mjcfec, Pmj35
  • Garland Fryer M35Ss
Write Your Own Review
You're reviewing:Frymaster 810-1873 Fryer Thermopile 36"
Your Rating
Customer Questions
What maintenance is required for the Frymaster 810-1873 Thermopile?

Periodically inspect the thermopile for secure connections and signs of corrosion. Test the voltage output to ensure proper gas valve operation. Clean surrounding components to prevent grease buildup that could affect thermopile performance.

What are common issues with the Frymaster 810-1873 Thermopile?

  • Thermopile failing to generate sufficient voltage.
  • Gas valve not opening properly.
  • Delayed burner ignition.
  • Burner shutting off unexpectedly.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas and electrical power to the fryer.

Step2: Remove the fry pot or top assembly to access the old thermopile.

Step3: Disconnect wires carefully from the existing thermopile.

Step4: Unscrew and remove the old unit from its mounting.

Step5: Install the new thermopile and reconnect wiring securely.

Step6: Restore power and gas, then test for proper pilot and ignition function.