Built for commercial food warming equipment, this high-limit thermostat checks cabinet temperature during heating operation. It is commonly installed in holding cabinets used in restaurants, cafeterias, catering kitchens, and other foodservice locations where warm food must stay at safe serving temperatures. The thermostat works as a safety control by stopping the equipment from getting too hot during use. If the thermostat becomes damaged or stops working correctly, the cabinet may overheat or fail to heat properly. Replacing a faulty high-limit thermostat can restore normal heating control and improve cabinet operation. Proper temperature control is important for safe food holding and steady heating performance in busy kitchen environments.
Equipment Compatibility:
Common applications for Intermetro High Limit Thermostat include heated holding cabinets, warming cabinets, and food warming equipment used in commercial kitchens and foodservice areas. This High Limit Thermostat RPC13-198 is compatible with commercial equipment from leading brands such as Intermetro and more, where temperature safety control and heating protection are required for proper equipment operation.
Brand Compatibility:
This high-limit thermostat replaces multiple part numbers used across compatible equipment applications from brands such as Intermetro. Complete cross-reference details are provided separately for identification and ordering purposes.
Product Specifications:
Manufacturer: Intermetro
SKU: RPC13-198
Product Type: High Limit Thermostat
Application: Commercial holding cabinets
Function: Temperature safety control
Installation Type: Replacement thermostat component
Key Features:
“After replacement, the warming cabinet maintained heat more consistently during service hours.”
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Step1: Turn off the power to the holding cabinet before starting installation.
Step2: Locate the existing hi-limit thermostat on the heating element.
Step3: Disconnect wiring carefully from the old hi-limit thermostat.
Step4: Remove the old thermostat from its mounting bracket or clip.
Step5: Install the new hi-limit thermostat in the same orientation.
Step6: Reconnect wiring securely to ensure proper electrical contact.
Step7: Restore power to the unit after installation is complete.
Step8: Test the hi-limit to confirm it trips at the proper temperature.