Vulcan Hart 00-428305-00001 Range Thermocouple 72" 20-30mV
Dimensions
- Length: 3 In
- Width: 2.5 In
- Height: 1 In
- Weight: 0.4 lbs
Product Notes
- Heavy-Duty 72" Thermocouple, 20-30 Milevolt.
- Coaxial Thermocouple Threads = 11/32"-32
We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More
We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More
This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More
Step1: Turn off gas supply and electrical power to range, allow appliance to cool completely before servicing.
Step2: Remove burner assembly or access panel to reach existing thermocouple connection at safety valve.
Step3: Disconnect old thermocouple from gas valve and pilot bracket, noting routing path.
Step4: Install thermocouple in same position, secure tip in pilot flame area, tighten connection to valve.
Step5: Restore gas supply, test ignition, and check for proper flame and no gas leaks using soapy water.