Pitco B6756601C Hi-Limit Service Kit

Special Price $228.45 Regular Price $440.00
In stock
SKU
B6756601C
Manufacturer:
The Pitco B6756601C Hi-Limit Service Kit works by sensing the temperature of oil or equipment and cutting off power to heating components in case the temperature is too high. When activated, it opens the circuit to avoid overheating in the course of using the fryer. This service kit is mounted within compatible fryers that are usually mounted in an area close to the heating system or thermostat. It connects with the control circuit of the fryer to provide over-temperature protection. The parts that are in the kit substitute or replace high-limit safety operations.

Dimensions

  • Length: 4 In
  • Width: 4 In
  • Height: 0.5 In
  • Weight: 0.25 lbs
https://partsfe.com/media/catalog/product/p/i/pitco-b6756601c-hi-limit-service-kit-for-pitco-fryers-96803-2.jpg

Product Notes

  • Hi-Limit Service Kit
  • Kit Includes Connectors, Brackets, Screws And Terminals
  • Pitco Fryer Me2, Meii, Se14, Se147, Se148X, Se14R, Se14T,
  • Se14Tr, Se14Tx, Se14X, Se18, Se18R, Se18S, Se714, Sebnb14,
  • Sebnb18, Seh50, Sfse14, Sfse14R, Sfse14T, Sfse14Tr,
  • Sfse14Tx, Sfse14X, Sfse18, Sfse18R, Sgh50
Write Your Own Review
You're reviewing:Pitco B6756601C Hi-Limit Service Kit
Your Rating
Customer Questions
What maintenance is required for the Pitco B6756601C Service Kit?

Inspect the fryer hi-limit assembly regularly for secure wiring connections and proper temperature cutoff function. Replace worn sensors or connectors during scheduled fryer servicing to ensure accurate safety operation. Keeping components clean and tightly fitted prevents overheating risks and maintains consistent fryer protection.

What are common issues with the Pitco B6756601C Service Kit?

  • Nuisance tripping causing fryer to shut down early.
  • Fryer failure to trip leading to overheating risk.
  • Loose or corroded wiring connections.
  • Inconsistent temperature sensing performance.
  • Damaged probe or connector causing intermittent operation.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off power and gas supply before starting the service procedure.

Step2: Access the component area and identify the parts being replaced.

Step3: Remove the existing components included in the service kit application.

Step4: Install the replacement parts from the kit according to their locations.

Step5: Tighten all fasteners and reconnect any removed connections.

Step6: Restore power and gas supply, then test the equipment for proper operation.