Dean 81006171 Thermopile 2 Lead 250-750 MV 36"

Special Price $64.48 Regular Price $83.75
In stock
SKU
81006171
Manufacturer:
The Dean 81006171 Thermopile is a high-quality 36” thermopile with a 2-lead, the purpose of which is to produce a voltage of between 250-750 millivolts. It is compatible with fryers, boilers, griddles and braising pans, and various other models such as Robertshaw, Cecilware, Cleveland, Groen, Imperial, Keating, Southbend, and many others. The thermopile is used to convert heat energy from a flame into electrical energy to proper ignition and stable burner operation. This product increases safety, productivity, and effectiveness, which means it is an essential element for ensuring stable functioning in conditions associated with intensive use of the kitchen.

Dimensions

  • Length: 3.5 In
  • Width: 2.5 In
  • Height: 1 In
  • Weight: 0.2 lbs
https://partsfe.com/media/catalog/product/d/e/dean-81006171-thermopile-2-lead-250-750-mv-36-24841-2.jpg

Product Notes

  • 36" 2 Lead, Thermopile, 250-750 Mv, Robertshaw 1950-53B
  • Cecilware Fryer Fmp 30, 40B, 403, 65, Fms 30, 54
  • Cleveland Boiler Gas Steam Generators: W/O Probes (100,000
  • Btu - 2 Burners~
  • 150,000 - 3 Burners)~
  • W/3 Probes (160,000
  • Btu - 3 Burners~
  • 200,000 - 4 Burners
  • Groen Braising Pan Hfp/2. Series: Chfp, Nhfp.
  • Imperial Fryer Series: If, Ihr, Ir.
  • Keating Griddle Model 48Bfld
  • Southbend Fryer Gfs, 4Fr-45
  • Star Fryer 404A, 615Fa, 630Fa
  • Tri-Star Fryer Tsf-3540, Tsf-4050, Tsf-6575
  • Vulcan Fryer: Tk, Rs, Ghf (Old Hf) Gr, Grd, Grc,Grs,
  • Wells Grill, Gas
  • Wolf Fryer Wtf-35,
Write Your Own Review
You're reviewing:Dean 81006171 Thermopile 2 Lead 250-750 MV 36"
Your Rating
Customer Questions
What maintenance is required for the Dean 81006171 Thermopile?

Clean the thermopile tip regularly to remove carbon buildup that can weaken millivolt output. Ensure proper flame impingement for stable signal generation. Inspect wiring connections for corrosion or looseness. Regular checks assist maintain accurate ignition performance and preventing intermittent appliance shutdowns.

What are common issues with the Dean 81006171 Thermopile?

  • Low millivolt output causing ignition failure or pilot dropout.
  • Carbon buildup on sensor reducing flame detection efficiency.
  • Loose or corroded lead connections interrupting signal flow.
  • Weak flame contact resulting in inconsistent heating operation.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas/electric and cool unit.

Step2: Remove access panel and disconnect old thermopile leads.

Step3: Unscrew and remove thermopile from pilot bracket.

Step4: Install new thermopile in same position ensuring flame contact alignment.

Step5: Route leads away from heat, connect securely to control module.

Step6: Restore gas, check pilot flame and verify MV output and safe operation.