Adcraft LCCM200300000 Hi-Limit Thermostat 1/4" X 4-1/2" 450°F 3/8" MPT CAP 30"

Special Price $149.84 Regular Price $230.88
In stock
SKU
LCCM200300000
The Adcraft LCCM200300000 H‍i-​Limit Th‍ermostat is an essential part designed to protect‍ the com​pati​bl‍e‌ commercial cooking equipment from overheating. Featuring​ a 1/4-⁠inch by 4-1/2-inch sensing elem​e‌nt, 3/8‌-inch MPT connection, and 30-inch capillary it monitors internal temperatures and interrupts operation when heat exceeds the 450°F limit. This co‍mpo​n‍ent is comm⁠only used in heated foodservice ap​plia​nces installed in restaurants and kitchen operations. Within the system it operates as a safe⁠t⁠y c⁠on⁠trol component that‌ supports regulating temperature cond‌itions‍ and protects heating and el‌ectrical components duri⁠ng co‌nti‍nuous operat‍ion.

Dimensions

  • Weight: 0.45 lbs
https://partsfe.com/media/catalog/product/a/d/adcraft-lccm200300000-hi-limit-thermostat-450-f-cap-30-76337.jpg
Provides high-temperature safety monitoring within compatible commercial kitchen equipment. The Adcraft LCCM200300000 Hi-Limit Thermostat 450°F 30" CAP detects excessive temperature through its sensing assembly and responds when the specified 450°F limit is reached. The 30-inch capillary connects the sensing element to the thermostat body, allowing temperature changes to be transmitted to the switching mechanism. When the safety threshold is reached, the thermostat interrupts the heating circuit to limit further heat input. It operates as an independent safety control alongside the equipment's primary temperature regulation system.

Overtemperature Protection:
Monitors temperature conditions and interrupts the heating circuit when the sensed temperature reaches the 450°F safety limit. The sensing assembly responds to temperature changes and transfers the thermal response through the capillary system to the thermostat mechanism. Once the specified limit is reached, the electrical contacts change state to stop power to the connected heating circuit. This independent cutoff function provides an additional layer of temperature control during abnormal or excessive heating conditions.

Safety Circuit Control:
Controls electrical continuity to the heating system when the detected temperature reaches the designated high-limit point. By interrupting the heating circuit during an overtemperature condition, the thermostat prevents continued heat input beyond its specified safety threshold.

Replacement Guidelines:
Replacement of the Hi-Limit Thermostat if it is damaged, unresponsive, worn, or no longer provides the intended high-temperature limit response. The part number LCCM200300000, 450°F temperature rating, and 30" capillary should be verified before replacement to ensure the correct hi-limit thermostat is selected. Replace the thermostat if deterioration affects temperature response, limit control, capillary integrity, electrical connection, or normal equipment operation.

Common Failure Symptoms:

  • Heating operation stops unexpectedly.
  • Heating components do not receive power.
  • Hi-limit protection does not respond correctly.
  • Incorrect high-temperature cutoff response.
  • Damaged or deteriorated capillary tube.
  • Visible damage to the thermostat assembly.

Equipment Compatibility:
The Adcraft LCCM200300000 Hi-Limit Thermostat is designed for compatible commercial kitchen equipment requiring a 450°F hi-limit thermostat with a 30-inch capillary. Verify the equipment model, part number, temperature rating, capillary length, and thermostat configuration before purchase.

Technical Specifications:
Brand: Adcraft
Part Number: LCCM200300000
Component Name: Hi-Limit Thermostat
Temperature Rating: 450°F
Capillary Length: 30" CAP

Write Your Own Review
You're reviewing:Adcraft LCCM200300000 Hi-Limit Thermostat 1/4" X 4-1/2" 450°F 3/8" MPT CAP 30"
Your Rating
Customer Questions
What signs indicate that the Hi-Limit Oven Thermostat might be malfunctioning?

Signs of a malfunctioning thermostat can include inconsistent temperature readings, overheating, longer cooking times, or frequent triggering of the safety switch. If you notice any of these issues, consider inspecting or replacing the thermostat.

Can the Hi-Limit Oven Thermostat be repaired, or does it need replacement if faulty?

In most cases, a faulty thermostat requires replacement rather than repair. Replacement ensures that the safety features and temperature control of the oven remain reliable.

Can I use a non-Adcraft thermostat as a replacement in my Adcraft oven?

It's recommended to use genuine Adcraft replacement parts, including thermostats, to ensure proper fit and compatibility. Non-Adcraft thermostats may not provide the same level of performance or safety.

What maintenance is required for the Adcraft LCCM200300000 Hi-Limit Thermostat?

Regularly inspect the thermostat capillary tube and sensing bulb for kinks, corrosion, or damage that could affect temperature sensing. Clean surrounding components to prevent grease buildup and overheating. Test the cut-off function periodically to ensure it trips near 450°F. Always disconnect power before servicing to prevent electrical shock or burns.

What are common issues with the Adcraft LCCM200300000 Hi-Limit Thermostat?

  • Failure to shut off at the set temperature.
  • Erratic temperature readings.
  • Loose or corroded electrical connections.
  • Sensor or cap damage affecting performance.

When should the Imperial 20160 Convection Oven Door Closing Mechanism be replaced?

The door closing mechanism should be replaced when it is worn, damaged, loose, or no longer allows the oven door to close and remain securely positioned.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step 1: Prior to starting the installation, ensure that the appliance is disconnected from the power source.

Step 2: Identify the current hi-limit thermostat located within the control or heater compartment of the equipment.

Step 3: Detach the old thermostat by disconnecting the wires and removing the fasteners used for mounting.

Step 4: Examine the replacement unit (LCCM200300000) alongside the original to confirm that it fits correctly and that the terminal arrangement matches.

Step 5: Install the new thermostat in the same location as the previous one, utilizing the appropriate screws or clips for secure mounting.

Step 6: Connect the wires to the designated terminals, making sure that the connections are tight and secure.

Step 7: Ensure that any sensing bulb or probe is positioned correctly in accordance with the specifications provided by the manufacturer.

Step 8: Reconnect the power supply and verify the functionality of the thermostat by heating the appliance to the required temperature and checking that it properly cuts off.