Comstock Castle COMT46 Thermocouple 18" 20-30mV 1980 Series

Special Price $18.28 Regular Price $23.75
In stock
SKU
COMT46
Manufacturer:
The Comstock Castle COMT46 Thermocouple 18" 20-30mV 1980 Series is a temperature sensor that is used in commercial systems. It works on the concept of producing a millivolt signal when hot and this keeps the gas valve open so long as a proper flame is maintained. It is installed close to the pilot burner in compatible appliances and constantly checks the status of the flame when it is in operation. This thermocouple is commonly found in professional kitchen ranges, and other equipment of this type and serves a safety purpose in the gas control system.

Dimensions

  • Length: 5 In
  • Width: 4 In
  • Height: 0.5 In
  • Weight: 0.1 lbs
https://partsfe.com/media/catalog/product/c/o/comstock-castle-comt46-1980-series-thermocouple-18-20-30mv-53075-2.jpg

Product Notes

  • 1980 Series Snap Fit 18" Thermocouple, 20-30 Mv
  • American Permanent Ware Griddle Ggm, Ggt
  • Comstock Castle Oven Bake, Barbeque & Pizza Ovens.
  • Series: C, D, F, K.
  • Dynamic Cooking Systems Oven All
  • Garland Broiler 6-40/50S, 7-40/50S, 8-40/50S, 60-40/50R
  • Oven Series: H281, P280. Standard Oven From 03/99 In
  • Canada Only, Range: G20-Sph
  • Imperial Model?
  • Star Fryer M14, Mi4 (D,Dl), M18, Mi8(D,Dl), M43, 215B, 216,
  • 403 404
  • Us Range Oven P-4-20.
  • Wolf Oven Ch, Chssd, R
AMERICAN RANGE:
10485, A11100, AMRA11100
ANETS:
ANEP8900-32, P8900-32
APW WYOTT:
CECILWARE:
COMSTOCK CASTLE:
DYNAMIC COOKING SYSTEMS:
IMPERIAL:
1121, 30030, IMP1121
ROYAL RANGE:
STAR MFG:
STERO:
STA2J-6726, STA2J6726, STA6726, STAH456
TRI-STAR:
310210, TRS310210
U-LINE:
1980-018
Write Your Own Review
You're reviewing:Comstock Castle COMT46 Thermocouple 18" 20-30mV 1980 Series
Your Rating
Customer Questions
What maintenance is required for the Comstock Castle COMT46 Thermocouple?

Inspect the thermocouple regularly for loose connections and corrosion to ensure accurate temperature readings. Clean the probe gently to remove grease or buildup affecting performance. Replace damaged wiring promptly to maintain safe and accurate operation.

What are common issues with the Comstock Castle COMT46 Thermocouple?

  • Inaccurate temperature readings due to worn thermocouple junction.
  • Intermittent signal loss from loose or damaged wiring.
  • Corrosion at probe tip affecting responsiveness.
  • Failure to ignite or control temperature properly in equipment.

We strive to provide our customers with a hassle-free and efficient shopping experience. Our shipping policy ensures the timely delivery of your orders and complete customer satisfaction. View More

We are committed to ensuring your complete satisfaction with every purchase. We understand that circumstances may arise where you must return a product or request a refund. If for any reason you are not satisfied, you may return the item(s) according to the terms outlined below. View More

This Payment Policy outlines the terms and conditions governing all payments made for products purchased through our website. By making a purchase, you agree to be bound by this Payment Policy. View More

Installation Steps

Step1: Turn off gas and power supply and let equipment cool.

Step2: Remove old thermocouple from pilot assembly.

Step3: Position new thermocouple tip in pilot flame area.

Step4: Secure connections to gas valve using correct fitting.

Step5: Tighten without over-torquing and check alignment.

Step6: Restore gas/power and test pilot ignition; ensure no leaks.

Step7: Wear gloves and ensure gas supply is fully shut off before testing.